logo
> 제품 > 모듈 무균실 >
SUS304 H14 Filter 99.9995% 0.3μm Class 100 Laminar Flow Hood for laboratory

SUS304 H14 Filter 99.9995% 0.3μm Class 100 Laminar Flow Hood for laboratory

원래 장소:

중국

브랜드 이름:

AMBER

인증:

CE,ISO, GMP

모델 번호:

AM-CB002

연락주세요

인용문을 요구하세요
제품 상세정보
필터 효율성:
99.9995% @ 0.3μm
마케팅 유형:
일반 제품
평가 된 전력:
200W 50Hz
유형:
클래스 100 층류 후드
신체 재료:
304 스테인레스 스틸
공기 조절:
HVAC시스템
조명:
LED 또는 형광등
부속품:
선반, 벤치, 공기 샤워 등
HEPA 필터:
H14
지불과 운송 용어
최소 주문 수량
1 평방 미터
포장 세부 사항
합판 케이스
지불 조건
L/C, D/A, D/P, T/T, Western Union, MoneyGram
공급 능력
한 달에 10000 평방 미터
제품 설명

 

Specifications
 

Material 304 stainless steel
Liquid tank HEPA filter specifications 1100*500*93
Efficiency 99.9995% @0.3μm H14
Power 200W 50HZ
Lamp Equipped with 1 germicidal lamp (optional)
Air speed 0.45-0.75m/s
Noise ≈60dB

 

 

 

SUS304 H14 Filter 99.9995% 0.3μm Class 100 Laminar Flow Hood for laboratory 0

 

 

High-precision manufacturing and life science experiments rely on air cleanliness to dictate the quality of research and production. The clean environment protection of laboratories and cleanrooms is the most strict with the Class 100 Laminar Flow Hood due to its efficient air filtration system and stable laminar flow system.

 

What is a Laminar Flow Hood?

 

A laminar flow hood features a powerful filter and fan system to provide clean air in a laminar flow in one direction and build a complete barrier of clean air in the operating area. It is able to efficiently remove airborne particles, microorganisms, and dust and is commonly employed in industries that demand an exceptionally high cleanliness of the air that must be used in their work, which include chip manufacture, pharmaceutical research and development, cosmetics manufacture, and food processing.

 

 

 

 

SUS304 H14 Filter 99.9995% 0.3μm Class 100 Laminar Flow Hood for laboratory 1

 

 

 

Class 100 Laminar Flow Hood Product Features

 

  • Modular design for easy transportation and installation, adapting to varying site layout requirements

 

  • Utilizes a dedicated laminar flow hood fan for high stability and low noise

 

  • A double-layer structure reduces fan vibration and noise, while maintaining a simple and aesthetically pleasing appearance

 

  • Equipped with a PAO test port for verifying installation reliability after filter replacement, and a differential pressure gauge for real-time monitoring of HEPA filter usage

 

  • Available configurations include side indoor return, top indoor return, side pipe return, and top pipe return, tailored to site requirements

 

  • Available mounting options include suspended and bracket mounting

 

  • Depending on the installation height, the IC control panel can be integrated with the laminar flow hood or a separate control box can be mounted at a suitable wall height

 

Application Areas

 

In electronics and semiconductors, or in pharmaceutical and medical laboratories that need cleanrooms to a degree of Class 100 conditions, the Laminar Airflow Workbench and Class 100 laminar flow hood can assist companies in designing high-level cleanrooms. Their modular structure enables them to be easily integrated in operating rooms, cleanrooms, or standalone laboratory space to suit the unique requirements of various customers.

 

Why choose us?

 

  • As a cleanroom engineering service provider with over 17 years of industry experience, we not only provide equipment but also offer complete, one-stop solutions.

 

  • Our professional design team supports customized cleanroom design drawings and provides on-site installation and commissioning to ensure equipment performance and cleanroom standards are met.

 

  • Long-term maintenance and technical support ensure the continued stability of production and testing.

 

Contact us now to create your customized Class 100 clean room.

 

 

SUS304 H14 Filter 99.9995% 0.3μm Class 100 Laminar Flow Hood for laboratory 2

 

 

FAQ

 

Q1: What is the difference between a Laminar Airflow Workbench and a Class 100 laminar flow hood?

A: Both operate on the same principle, creating a dust-free environment through unidirectional clean air flow. The difference lies in their application scenarios: Laminar Airflow Workbench units are typically desktop-style and suitable for laboratory operations, while Class 100 laminar flow hoods are modular, ceiling-mounted units more suitable for building integrated cleanroom systems in cleanrooms or operating rooms.

 

Q2: Will the noise from the equipment affect laboratory personnel's work?

A: The operating noise level of a laminar flow hood is approximately 60dB, equivalent to the sound level of normal conversation. This level will not disturb laboratory personnel and is suitable for extended work.

 

Q3: Is customization available?

A: With over 17 years of industry experience, we offer customized solutions tailored to your specific needs, including dimensions, filter configuration, and germicidal lamp options. We also provide design drawings and on-site installation services.

직접적으로 당신의 조사를 우리에게 보내세요